Inspect the continuous tube-in-tube sterilization system: product feed, indirect heating, holding, cooling, controls, cleaning and the aseptic transfer interface.
Sterilization / UHT evidence
Separate residue removal from pre-sterilization and document the complete connected path.
Include the vessel, pump, tube bank, valves, instruments, return line and drain points. Record which parts need opening or removal. A CIP connection does not establish coverage of every product-contact surface.
Use the agreed product residue, solution, temperature, supply/return flow, contact time and rinse endpoint. Retain the verification method and result. Do not copy a generic cleaning recipe to a different soil or material.
Identify the downstream boundary, vent and condensate paths, sensors, completion criteria and permitted transition to product. A completed cleaning cycle is not proof of sterilization. The supplier and process authority should allocate the acceptance responsibilities.
Download the blank data sheet, scope matrix and RFQ checklist. Record missing values as unknown. The worksheet contains no measured results.